Glossary
Definitions for every TMA-specific term: Apply, Controller, Viewer, Session ID, INOP, NIBP, Trend Apply, V/NV, and more.
Written By LJ Merchant
Last updated 1 day ago
Glossary
Quick definitions for every TMA-specific term.
- AED Trainer β The Display Monitor panel that simulates AED operation (Standby β Attach Pads β Analyze β Shock). Enabled via Display Controls on the Controller.
- Apply New Vitals β The Controller button that pushes staged numeric values from the New column to the Display Monitor. Nothing numeric changes on the Display until this is clicked.
- AUTO (BP) β The auto-cycle mode for NIBP. Cycles through OFF, 5 min, 10 min, 15 min. When active, automatically takes a BP reading at the chosen interval.
- Battery β The simulated monitor battery. Drain mode depletes at 1%/min; Charge mode adds 5%/min. At 0%, the Display Monitor shows DEVICE OFF.
- Controller (screen) β The instructor remote at /controller. Where you change vitals, rhythms, alarms, and all session settings.
- Controller (permission) β A user who can access both the Controller screen and the Display Monitor, and can manage other users.
- Crisis Alarm β Red alarm. Fires when a vital is out of range for 5 or more seconds. Outlines the affected vital in red on the Display Monitor.
- Current column β The "what is currently displayed" column in the Vital Values table. Reflects the last Applied value.
- DEVICE OFF β The state of the Display Monitor when battery reaches 0%. The screen goes dark until the battery is charged above 0% via the Battery tab.
- Display Controls β A modal on the Controller with toggles for: Display Monitor on/off, AED Trainer on/off, Rhythm Identification on/off, NIBP Auto Cycle on/off.
- Display Monitor (screen) β The student-facing patient monitor at /display. Shows ECG, SpO2, EtCO2, BP, Temp, Glucose, and more.
- Ectopy β Extra beats overlaid on the underlying rhythm. Options: Monomorphic, Polymorphic, None.
- End Trend β Stops an active trend immediately. Vitals stay at their current mid-trend value and do not revert.
- Immediate Apply β The default Apply mode. Vitals change instantly when Apply is clicked.
- INOP β "Inoperable." A simulated sensor disconnect. The affected vital shows dashes (---) and an INOP alarm fires.
- MAP β Mean Arterial Pressure. Auto-calculated from Systolic and Diastolic BP.
- Multi-Session Controller β The ability for one Controller to manage multiple simultaneous sessions from one device, switching via the session dropdown.
- New column β The "what is staged" column in the Vital Values table. Reflects what the instructor has set but not yet Applied.
- NIBP β Non-Invasive Blood Pressure. TMA's BP model: values are hidden until measured by pressing the NIBP button, mirroring how a real NIBP cuff works.
- Original Owner β The user who created the session. Has permanent Controller access and cannot be demoted or removed by anyone.
- Patient Population Preset β Pre-configured alarm thresholds for an age band. Options: Adult (β₯13), Pediatric Infant (1β12 months), Pediatric Child (1β7 years), Pediatric Adolescent (8β12 years), Neonatal (0β28 days), Custom.
- Pleth β Plethysmograph. The SpO2 waveform displayed on the monitor.
- Pleth Amplitude β Height of the pleth waveform (0β100%). Lower values simulate weak peripheral perfusion.
- Pleth Morphology β Shape of the pleth waveform. Options: Normal, Bisferiens, Pulsus Alternans.
- PTT (Pulse Transit Time) β Delay between the ECG R-wave and pulse arrival at the SpO2 sensor. Normal: 200β300ms. Longer = low perfusion/shock. Shorter = arterial stiffness.
- QRS Beep β An audio heartbeat tone played after each QRS complex. Toggle in the Audio tab.
- Rhythm Identification β The on-monitor label naming the current rhythm (e.g. "Sinus"). Toggle off in Display Controls to quiz students.
- Session β The container for one simulation. Holds all vital values, rhythm, alarm settings, battery state, user list, and the Session ID. Server-authoritative.
- Session ID β The short alphanumeric code identifying a session (e.g. K1KYW1). Case-insensitive. Never contains O or 0.
- Shock Outcome β The rhythm the patient converts to when the AED Trainer delivers a shock. Set on the Controller; options include No Effect, Normal Sinus, Sinus Tachycardia, V-Tach, V-Fib, Asystole.
- Silence (button) β On the Display Monitor, temporarily silences the currently sounding alarm. The next new alarm will still sound.
- SpCO β Carboxyhemoglobin. Displayed when set above 0. Used for CO poisoning scenarios.
- Trend Apply β An Apply mode that animates vitals from current to target over a chosen duration (3β300 seconds) rather than changing them instantly.
- V/NV β Visible / Not Visible toggle per vital on the Controller. NV hides the vital from the Display Monitor entirely β the cell appears blank.
- Viewer (permission) β A user with Display Monitor access only. The Control Vital Signs tab is hidden from their header. Read-only.
- Vital Values Table β The two-column table on the Controller showing Displayed (current) and New (staged) values for every vital.
- Warning Alarm β Yellow alarm. Fires when a vital is out of range for 10 or more seconds.
- Welcome Back modal β Appears on return visits when a previous session is still active. Offers to Continue Previous Session or Start New Session.